export@ngi-tech.com
English
Current Location:

N3600 Series Wide Range High Voltage Programmable DC Power Supply

N3600 series is a wide-range programmable DC power supply. Its output current range is 5A to 1500A, output voltage range is 16V to 1200V, and output power range is 800W to 9kW. It supports cascade mode, CC/CV/CP mode, SEQ test and external programming. N3600 with wide range, multi-function, high performance and high reliability can be used in new energy, industrial automation, etc.

Search by model
Showing 0 results
ModelChannel NumberVoltageCurrent PowerAccuracyResolution Communication InterfaceSize
N3608-080-060180V60A800WVoltage≤0.03%+20mV/Current≤0.1%+60mA10mV/30mARS232/USB/GPIB2U
N3612-080-060180V60A1,200WVoltage≤0.03%+20mV/Current≤0.1%+60mA10mV/30mARS232/USB/GPIB2U
N3612-240-0301240V30A1,200WVoltage≤0.03%+60mV/Current≤0.1%+30mA30mV/15mARS232/USB/GPIB2U
N3618-080-120180V120A1,800WVoltage≤0.03%+20mV/Current≤0.1%+120mA10mV/60mARS232/USB/GPIB2U
N3618-240-0601240V60A1,800WVoltage≤0.03%+60mV/Current≤0.1%+60mA30mV/30mARS232/USB/GPIB2U
N3618-500-0201500V20A1,800WVoltage≤0.03%+125mV/Current≤0.1%+20mA62.5mV/10mARS232/USB/GPIB2U
N3618-750-0151750V15A1,800WVoltage≤0.03%+180mV/Current≤0.1%+16mA90mV/8mARS232/USB/GPIB2U
N3618-1000-01011000V10A1,800WVoltage≤0.03%+250mV/Current≤0.1%+10mA125mV/5mARS232/USB/GPIB2U
N3630-080-120180V120A3,000WVoltage≤0.03%+20mV/Current≤0.1%+120mA10mV/60mARS232/USB/GPIB2U
N3630-240-0601240V60A3,000WVoltage≤0.03%+20mV/Current≤0.1%+120mA10mV/60mARS232/USB/GPIB2U
N3630-500-0201500V20A3,000WVoltage≤0.03%+125mV/Current≤0.1%+20mA62.5mV/10mARS232/USB/GPIB2U
N3630-750-0151750V15A3,000WVoltage≤0.03%+180mV/Current≤0.1%+16mA90mV/8mARS232/USB/GPIB2U
N3630-1000-01011000V10A3,000WVoltage≤0.03%+250mV/Current≤0.1%+10mA125mV/5mARS232/USB/GPIB2U
Features
■ Voltage range: 16V-1200V

■ Current range: 5A-1500A
■ Power range: 800W-9kW
■ Multiple devices operation in cascade mode, up to 90kW
■ CC, CV and CP mode
■ Sequence test function(SEQ), up to 100 groups sequence files, up to 100 steps per file
■ Editable rise/fall slew rate
Convenient HMI (human-machine interaction) interface on LCD screen
Equipped with LCD screen, numeric buttons and knob to support local operation
External dissipater to protect the power supply and DUT
Standard 19-inch chassis, available for benchtop or rack installation
Built-in RS232/LAN communication interface
Multiple protections: OCP, OVP, UVP, OTP, OPP, peripheral control communication error alarm
Analog programming (APG) interface, current monitoring interface, remote trigger function to realize complex function control and monitoring

Functions & Advantages

SEQ function

SEQ function provides setting of output voltage, output current, voltage slew rate, current slew rate and dwell time for single step.


Voltage up to 1200V, making high voltage test more secure

N3600 series supports up to 1200V. In the fields of LED, battery, DC/DC converter and other industries, high voltage is the basic need for power supplies. Besides the above mentioned industries, N3600 series can also be applied for special tests with extremely high voltage requirements.

The safety of high-voltage test has always been a concern of engineers. NGI puts emphasis on details like the safety terminals design to ensure the safety of the test.


Wide range for saving purchase cost

N3600 series' Max. power is not the result of Max. voltage multiplied by the Max. current. Take model N3630-240-060 for example. The Max. power is 3kW while the Max. voltage 240V and Max. current 60A. The single model can replace two devices or more common power supplies.



External dissipater function

When using N3600 to supply power to inductive loads such as motors, users press ON/OFF button on N3600’s front panel to stop power supply. At this time, the motor may return a voltage greater than the setting value of N3600, which is likely to damage N3600 and the motor. Users can connect a load to N3600 as a dissipater. The setting voltage of the load must be an increment higher than the setting voltage of N3600. When the setting voltage of the load is higher than the setting voltage of N3600, the load will not work. If the voltage returned by the motor is exceeding the setting voltage of the load, the load starts to work to protect N3600 and the motor controller.


Application Fields

■  New energy fields, such as Li-on battery, photovoltaic, hydrogen fuel, energy storage BMS, etc.

■  Civil fields, such as home appliances, consumer electronics, communications, etc.
■  Laboratory, production line ATE automatic test system
■  Automotive fields, such as BMS, DC-DC, automotive electronics, etc.
■  Testing and powering of aerospace electronics
■  Industrial automation fields, such as controllers, drives, servers, robots, etc.
Dimension
Standard & Optional Accessories
Database

Data Sheet

User Manual

Communication Protocol

Software & Driver

Application

Related Products
Do you want to log out?

Member Login

Haven't got an account? Register now.

Inquiry

Email

export@ngi-tech.com