/ EN
Current Location:
<
>

N68000 Series High Power DC Electronic Load

N68000 Series High Power DC Electronic Load

N68000 Series High Power DC Electronic Load

N68000 Series High Power DC Electronic Load

N68000 Series High Power DC Electronic Load

N68000 Series High Power DC Electronic Load

N68000 Series High Power DC Electronic Load

N68000 Series High Power DC Electronic Load

<
>

N68000 Series High Power DC Electronic Load

N68000 series is developed based on NGI's years of experience in testing for power supply, car charger, battery and supercapacitor. It is with high accuracy, high reliability and high cost performance.It has CC, CV, CP and CR mode. N68000 series supports SEQ test, dynamic test, charge test, discharge test, OCP test, etc. The power range covers from 2.4kW to 14.4kW.

Data Sheet

User Manual

Product Video

Inquiry

http://ngitech.oss-accelerate.aliyuncs.com/upload/202404/29/202404291407544749.mp4
Search by model
ModelChannel NumberVoltageCurrent PowerAccuracyResolution Communication InterfaceSize
N68024-150-2001150V200A2,400WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN3U
N68024-150-0601150V60A2,400WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/0.1mALAN/RS232/CAN3U
N68024-600-0201600V20A2,400WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/0.1mALAN/RS232/CAN3U
N68024-600-0601600V60A2,400WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/0.1mALAN/RS232/CAN3U
N68024-1000-02011000V20A2,400WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/0.1mALAN/RS232/CAN3U
N68024-1000-06011000V60A2,400WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/0.1mALAN/RS232/CAN3U
N68036-150-3001150V300A3,600WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN3U
N68036-150-0901150V90A3,600WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/0.1mALAN/RS232/CAN3U
N68036-600-0301600V30A3,600WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/0.1mALAN/RS232/CAN3U
N68036-600-0901600V90A3,600WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/0.1mALAN/RS232/CAN3U
N68036-1000-03011000V30A3,600WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/0.1mALAN/RS232/CAN3U
N68036-1000-09011000V90A3,600WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/0.1mALAN/RS232/CAN3U
N68048-150-4001150V400A4,800WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN6U
N68048-150-1201150V120A4,800WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN6U
N68048-600-0401600V40A4,800WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/0.1mALAN/RS232/CAN6U
N68048-600-1201600V120A4,800WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN6U
N68048-1000-04011000V40A4,800WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/0.1mALAN/RS232/CAN6U
N68048-1000-12011000V120A4,800WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/1mALAN/RS232/CAN6U
N68060-150-5001150V500A6,000WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN6U
N68060-150-1501150V150A6,000WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN6U
N68060-600-0501600V50A6,000WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/0.1mALAN/RS232/CAN6U
N68060-600-1501600V150A6,000WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN6U
N68060-1000-05011000V50A6,000WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/0.1mALAN/RS232/CAN6U
N68060-1000-15011000V150A6,000WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/1mALAN/RS232/CAN6U
N68072-150-6001150V600A7,200WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN6U
N68072-150-1801150V180A7,200WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN6U
N68072-600-0601600V60A7,200WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/0.1mALAN/RS232/CAN6U
N68072-600-1801600V180A7,200WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN6U
N68072-1000-06011000V60A7,200WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/0.1mALAN/RS232/CAN6U
N68072-1000-18011000V180A7,200WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/0.1mALAN/RS232/CAN6U
N68084-150-7001150V700A8,400WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN9U
N68084-150-2101150V210A8,400WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN9U
N68084-600-0701600V70A8,400WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/0.1mALAN/RS232/CAN9U
N68084-600-2101600V210A8,400WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN9U
N68084-1000-07011000V70A8,400WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/0.1mALAN/RS232/CAN9U
N68084-1000-21011000V210A8,400WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/1mALAN/RS232/CAN9U
N68096-150-8001150V800A9,600WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN9U
N68096-150-2401150V240A9,600WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN9U
N68096-600-0801600V80A9,600WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/0.1mALAN/RS232/CAN9U
N68096-600-2401600V240A9,600WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN9U
N68096-1000-08011000V80A9,600WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/0.1mALAN/RS232/CAN9U
N68096-1000-24011000V240A9,600WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/1mALAN/RS232/CAN9U
N68108-150-9001150V900A10,800WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN9U
N68108-150-2701150V270A10,800WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN9U
N68108-600-0901600V90A10,800WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/0.1mALAN/RS232/CAN9U
N68108-600-2701600V270A10,800WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN9U
N68108-1000-09011000V90A10,800WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/0.1mALAN/RS232/CAN9U
N68108-1000-27011000V270A10,800WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/1mALAN/RS232/CAN9U
N68120-150-10001150V1000A12,000WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/10mALAN/RS232/CAN12U
N68120-150-3001150V300A12,000WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN12U
N68120-600-1001600V100A12,000WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN12U
N68120-600-3001600V300A12,000WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN12U
N68120-1000-10011000V100A12,000WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/1mALAN/RS232/CAN12U
N68120-1000-30011000V300A12,000WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/1mALAN/RS232/CAN12U
N68132-150-11001150V1100A13,200WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/10mALAN/RS232/CAN12U
N68132-150-3301150V330A13,200WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN12U
N68132-600-1101600V110A13,200WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN12U
N68132-600-3301600V330A13,200WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN12U
N68132-1000-11011000V110A13,200WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/1mALAN/RS232/CAN12U
N68132-1000-33011000V330A13,200WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/1mALAN/RS232/CAN12U
N68144-150-12001150V1200A14,400WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/10mALAN/RS232/CAN12U
N68144-150-3601150V360A14,400WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN12U
N68144-600-1201600V120A14,400WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN12U
N68144-600-3601600V360A14,400WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.1mV/1mALAN/RS232/CAN12U
N68144-1000-12011000V120A14,400WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/1mALAN/RS232/CAN12U
N68144-1000-36011000V360A14,400WVoltage≤0.05%+0.05%F.S./Current≤0.05%+0.1%F.S.10mV/1mALAN/RS232/CAN12U

Show All

Features
Power range: 2.4kW to 14.4kW
Voltage range: 150V/600V/1000V
Operation modes: CC/CV/CR/CP
High power density, minimizing space occupation
CR/CP function supported by hardware
Charge test, Discharge test and OCP test
Transient over-power loading capability
Built-in ESR test function(Optional)
Editable rise and fall slew rate
Editable Von/Voff
Comprehensive MOS protection
Programmable sequence test function(SEQ), up to 100 groups sequence files, up to 50 steps per file
Multiple protection: OCP, OVP, OTP, OPP and reverse polarity warning
Analog programming interface(APG), current monitoring interface, and remote/local trigger function
Multiple communication interfaces: LAN/RS232/CAN
Functions & Advantages
High reliability design

N68000 series has a comprehensive MOS protection circuit. No matter how much MOS is damaged, it will not cause short-circuit between the positive and negative polarity or the positive polarity and the control circuit. The damage of some MOSs does not accelerate the damage of others, which can be used continuously.


By distributed design, it is easy to replace or add power modules and is convenient for maintenance and power expansion.

N68000 is designed with power limit circuit and has fast response, which can prevent the load from being damaged due to over power.
N68000 adopts shielding technology, which has wide adaptability to harsh test environment, and improves the anti-interference ability.


Short-circuit function
N68000 series supports two modes for short circuit: manual and lock.

Manual: N68000 will be short-circuited when Short button is pressed.It will stop short-circuiting when button is released. Manual mode is suitable for debugging or R&D, avoiding measurement accidents dueto misoperation.

Lock: N68000 will keep short-circuiting when Short button is pressed.It will stop short-circuiting when the button is pressed again. Lock mode is suitable for long-time short-circuit test.


Dynamic modev

N68000 series provides three options for dynamic: continuous, toggle and pulse. The dynamic rate is up to 20kHz and can be adjustable.This function is often used to test power supply transient performance,battery protection board protection performance and battery pulse charging.



Transient over-power loading capability

In transient high power applications, users do not need to select models according to the Max. power. Take DC motor start-up simulation for example. The transient power at start-up is usually several times of the rated power. It can also test the transient overload performance of power supplies and the transient high-power discharge of power batteries.


External programming

Users can control load voltage and current via external analog input. 0-10V input through the external programming interface corresponds to 0-full scale output on the load.



Current monitoring

0-10V analog output at the current monitoring output terminal corresponds to 0-full scale current. Users can use a voltmeter or oscilloscope to monitor the current variation.



Programmable slew rate

Rise and fall slew rates are settable to prevent overshoot and meet different test demands.

The conversion slew defines the current or voltage transition rate when the on-load main value of N68000 changes. When the slew is set to the maximum value, the transition time between the main value and the transient value is minimal.


Application Fields
Charging station, car charger
DC-DC power supply, server power supply
Communication power supply capacitor module, battery pack
High current relay
Energy storage system


Dimension
Standard & Optional Accessories
Database

Data Sheet

User Manual

Communication Protocol

Software & Driver

Application

Related Products
English 中文

Do you want to log out?

Member Login

  • Email ID

  • Password

Haven't got an account? Register now.

Inquiry

Email