Do you want to log out?
Standalone input power: 2~60kW, 3U/6kW high power density
Voltage range: 0~150V/0~600V/0~1200V
Current range: up to 2500A
CV, CC, CP, CR three ranges, wide measurement range
Current measurement accuracy: 0.04%+0.04% F.S.
Voltage measurement accuracy: 0.015%+0.015% F.S.
1.6 times power loading capacity in a short time (<3s)
Adjustable CV loop speed, matching different power supplies
Voltage/current sampling rate: up to 500kHz
Supporting parallel control, and realizing power expansion via master+master, master+slave
Supporting SEQ test, discharge test, charge test, OCP/OPP test and short-circuit simulation
Operation modes: CC, CV, CP, CR, CV+CC, CR+CC, CV+CR, CP+CC
Supporting current monitoring output, external programming input, external trigger input, and 10kHz sine wave programming input
30kHz high-speed dynamic mode, dynamic frequency sweep function
Time measurement, rise/fall time measurement accuracy: 10μs
Arbitrary waveform load test (Optional), sine wave up to 20kHz, supporting USB flash drive import
Equivalent series resistance( ESR) test (Optional)
Soft on/off function, current oscillation protection function
Multiple protection: OCP, OVP, OPP, OTP and reverse connection detection
Supporting 100 groups of parameters to be saved and fast recalled
LAN/RS232/CAN as standard interface, GPIB as optional interface
Supporting MPPT maximum power point tracking function
3U/6kW, ultra-high power density
N69200 is designed with high power density. Power of 19” 3U chassis can be up to 6kW. The volume and weight are half of traditional electronic loads. Compared with traditional electronic loads with the same power, N69200 is smaller in size and lighter in weight.
Parallel connection for power extension
N69200 supports parallel connection. When the load power needs to be increased, models with the same voltage specification can be connected in parallel (master + master, master + slave) to achieve the required current and power. When using N69200, users only needs to set current on the master. The slave current will be distributed automatically, which simplifies the operation steps.
Multiple operation modes
N69200 supports four normal working modes: CC, CV, CP, and CR. In order to cope with the change of load characteristics in the actual test process, N69200 has also been developed with CV+CC, CR+CC, CV+CR, CP+CC four combined working modes. For example, CR+CC is suitable for the startup test of power supply to prevent overcurrent protection when the power supply is turned on. CV+CR can replace the setting application of Von point. CV+CC can simulate the working mode transition process of battery charging. Users can choose different working modes for test according to their actual situation.
High speed dynamic mode, with dynamic frequency sweep
N69200 has a high-speed dynamic mode. The dynamic characteristics of the DC power supply can be tested by simulating the dynamic load behavior of the power supply through the dynamic mode. N69200 provides dynamic frequency sweep and programmable dynamic mode up to 30kHz, including CCD constant current dynamic, CVD constant voltage dynamic, CRD constant resistance dynamic, and CPD constant power dynamic. Programmable dynamic load mode allows setting of high/low range, rise/fall slew rate, pulse width and operation mode. The voltage and current sampling rate of dynamic frequency sweep mode is 500kHz. It supports linearly changing the frequency of the load current. Frequency is up to 30kHz. This mode can measure the peak voltage Vpk+, valley voltage Vpk- and occurrence frequency points of the DUT during the dynamic frequency load change process.
Charge & discharge test
Users can set different conditions on the front panel to meet their test demands. For example, when battery voltage is lower than initial voltage, N69200 internal counter will start counting. The counter will stop working until the battery voltage drops to cut-off voltage.
OCP( over current protection) test
During OCP test, N69200 will load under CC mode and check whether the DUT voltage is lower than cut-off voltage. If lower, N69200 will record the present loading current as the test result and shut the input to stop the test. If the DUT voltage is higher than cut-off voltage, N69200 will increase the loading current until the DUT voltage is lower than cut-off voltage or it reaches the Max. loading current.
Equivalent Series Resistance( ESR) test (Optional)
ESR is a principal parameter of battery or supercapacitor. N69200 series offers professional ESR measurement function, which can support multiple measurement standards, and possess the advantages of accurate results and stable repeated results.
New energy fields, such as fuel cell stacks and engines, lithium battery packs, supercapacitors, photovoltaic modules, etc.
High-power DC power supply, such as industrial power supply, server power supply, communication power supply, etc.
Power electronic products, such as UPS power supply, DC-DC converter, on-board charger, etc.
Power supply, such as generator set, energy storage system, DC charging pile, etc.
DC high-power devices, such as contactors/relays, automotive high-voltage accessories, etc.