export@ngitech.cn
English
  • Difference between linear power supply and switching power supply

    October 07, 2020

    Linear power supplies take an AC input, step down the voltage via a transformer, then rectify and filter the input into a direct current output.

    Switching power supplies take an AC input, but rectifies and filters into DC first.  Next this DC power is switched to a higher frequency through a switching circuit. It steps down the voltage with a transformer, then is rectified and filtered into a DC output. 

    Fold
  • Effects of ripple and noise

    September 22, 2020

    1) Reduces the efficiency of power supply.

    2) Noise interference will cause instability of audio and video.

    3) It will increase the heating and reduce the lifetime.

    4) Interferes with the logic circuit and affect the normal operation of circuit.

    Fold
  • What is temperature coefficient?

    September 07, 2020

    Temperature coefficient describes the relative change of a physical property which is associated with temperature variation.

    Fold
  • What is slew rate?

    September 03, 2020

    Slew rate is defined as the rate of voltage or current change per unit time.

    Fold
  • What is transient recovery time?

    September 02, 2020

    Transient recovery time is a duration required for the power supply to recover to its specified level after loading.

    Fold
  • There is communication failure on N6900.

    April 07, 2020

    1) Please set Communication Protocol to MODBUS on System Configuration, if communicating via LAN port.  

    2) Please confirm Baud Rate on both System Configuration and N6900 application software, if communicating via RS232 interface.

    3) Please confirm ID and Baud Rate on both System Configuration and N6900 application software, if communicating via CAN interface.

    Fold
  • Why is N6900 fan speed too high when power-on?

    December 17, 2019

    1) The Ethernet cable was plugged into EXTEND port.


    2) There is OTP warning on the screen. Please calibrate the temperature.



    Fold
  • There is no response after pressing On/Off button when N6900 is under CC/CV/CP mode.

    December 17, 2019

    N6900 is under external control. Please restore factory setting and restart N6900.

     

    Fold
  • There is OVP warning on the screen. N6900 cannot sink current.

    December 17, 2019

    1) The OVP value is improperly set.  

    2) The input voltage exceeds N6900 rated voltage.

    Fold
  • The displayed value is inconsistent with actual value on N6900.

    December 17, 2019

    1) Please set the Operation Mode to High Accuracy on Application Setting. 

    2) Please calibrate the device.

     

    Fold